← Research libraryAluminium threads — strength cheatsheet
Effective thread shear area, engagement, bolt strength and preload. Original supplied reference, preserved unchanged.
Download original PDF · Interactive explainer · Current Cycle 18 per-bolt calculation and formulas (tailnet access)
The current design check separately reports capacity divided by two, combined bolt yielding and receiver-thread yielding. Material certificates, installed preload and contact/prying remain necessary to qualify an actual connection.